Facility Details: ACHILLES

Organization / Localization: AEA
Country: UK
Test Identification: A1R030
SA-Related Topics / Phenomena: cooling of intact fuel rods during a postulated LOCA in PWR
Measured Parameters: Reflooding of un-ballooned rods bundle (water forced convection regime)
References: Holmes, B.J., 1991. ISP 25 Comparison Report. AEE, Winfrith, Dorchester, UK.
IP/Copyright Situation: To be Checked
Organization / Localization: AEA
Country: UK
Test Identification: A2R038
SA-Related Topics / Phenomena: cooling of ballooned fuel rods during a postulated LOCA in PWR
Measured Parameters: Reflooding of ballooned rods bundle (water forced convection regime)
References: Holmes, B.J., 1991. ISP 25 Comparison Report. AEE, Winfrith, Dorchester, UK.
IP/Copyright Situation: To be Checked




Implemented as part of the Seaknot EU funded project (HORIZON-EURATOM-2021-NRT-01 under Grant Agreement No. 101060327) - WP2.6 UNIPI (2024-2026)