Facility Details: CCL

Organization / Localization: Canadian Nuclear Laboratories (formerly AECL)
Facility Description: Small scale facilties. Key facilities included Co-60 irradiators (Gammacells), active laboratories for performing iodine-131 tracer studies, specialised surface science laboratories (capable of working on active or inactive samples) and extensive hot cell
Test Identification: Several tests named according to the serie: ORGx-G, ORGx-A, ORGx-M; A-x, G-x
SA-Related Topics / Phenomena: Adsorption of iodine on paint surfaces and formation of organic iodine species.
Measured Parameters: Temperature, coupon surface morphology, penetration depth of iodine, radiation dose rate
Modelling: Gamma radiation, temperature, relative humidity and carrier-gas composition
Simulation Code: COCOSYS
Experimental Research Program: Behaviour of Iodine Project (BIP)
Link to PIRT: In total three project phases: BIP-1 to BIP-3.
References: [1] https://www.oecd-nea.org/jcms/pl_24819/behaviour-of-iodine-project-bip
[2] NEA, Behaviour of Iodine Project: Final Summary Report, OECD Publishing, Paris, 2012
[3] NEA, International Iodine Workshop: Full Proceedings, pp. 37-38 and pp. 153-164. OECD Publishing, Paris, 2016
[4] NEA, Behaviour of Iodine Project 3: Final Summary Report, OECD Publishing, Paris, 2023
[5] https://www.cnl.ca/facilities/containment-chemistry-laboratory-ccl/
[6] Kecek, A., Validation of COCOSYS 2.4v4 AIM module on various single effect and integral experiments, Kerntechnik 84, 5, 425-433, 2019. https://doi.org/10.3139/124.190045





Implemented as part of the Seaknot EU funded project (HORIZON-EURATOM-2021-NRT-01 under Grant Agreement No. 101060327) - WP2.6 UNIPI (2024-2026)