DataBase Source Term - Focus area 4: Fission product mitigation actions (e.g. FCVS, spray) and containment bypass scenarios (1)
Organization / Localization:
Harbin Univ.
Country:
China
Facility Description:
Venturi diameter 40 mm
SA-Related Topics / Phenomena:
Aerosol retention in self-priming venturi
Modelling:
10-1200 kg/h air flow rate; unsubmerged venturi
Show/Hide Additional Details ▼
References:
[1] http://dx.doi.org/10.1016/j.pnucene.2015.09.009