Facility Details: PERSEE and SAFARI exp. Loops

Organization / Localization: ASNR
Country:
Facility Status:
DataBase Source Term - Focus area 4: Fission product mitigation actions (e.g. FCVS, spray) and containment bypass scenarios (1)
Facility Description: Loop to check efficiency of filtration for gas filters
Test Identification:
SA-Related Topics / Phenomena:
Measured Parameters: Filtering efficiencies of volatile iodine (I2 and CH3I) with different porous materials in temperature and various gas composition (air, H2O …)
Modelling:
Simulation Code:
Experimental Research Program: MiRE RSNR project (2014-2022)
Link to PIRT: ST-54
Show/Hide Additional Details ▼
References: [1] M. Chebbi et al., Effects of water vapour and temperature on the retention of radiotoxic CH3I by silver faujasite zeolites. Journal of Hazardous Materials 409 (2021) 124947. https://doi.org/10.1016/j.jhazmat.2020.124947
[2] Azambre, B., M. Chebbi et al. (2018). Effects of zeolitic parameters and irradiation on the retention properties of silver zeolites exposed to molecular iodine.
[3] Ind. Eng. Chem. Res. 57 (5), 1468–1479. https://doi.org/10.1021/acs.iecr.7b03579 3) T. Albiol et al. Main results of the European PASSAM project on severe accident source term mitigation. Annals of Nuclear Energy 116 (2018) 42–56. https://doi.org/10.1016/j.anucene.2018.02.024
Contributed By: L. Cantrel
IP/Copyright Situation: upon request and partially published




Implemented as part of the Seaknot EU funded project (HORIZON-EURATOM-2021-NRT-01 under Grant Agreement No. 101060327) - WP2.6 UNIPI (2024-2026)