Facility Details: SICOPS (Metal-oxide mixing)

Description: 1D cold crucible with zirconia-shielded inside, stratified metal-oxide melt with gas injection through the bottom
Organization / Localization: Framatome GmbH, Radiochemical Lab
Molten Corium Concrete Interaction- (MCCI) (1)
Test Identification: Variation of gas rate and oxide density
SA-Related Topics / Phenomena: Metal oxide mixing during late MCCI
Measured Parameters: Melt temperature, online sampling, heat-fluxes
Modelling:  
Simulation Code: COSACO
Experimental Research Program: co-funded by BMWi
Show/Hide Additional Details ▼
References: S. Hellmann, G. Langrock, "MCCI Experiments With Oxidic/Metallic Mixed Melts", Final report, Framatome / BMWi project 1501317, January 2011
Comments:  
Contributed By: T. Keim/M. Fischer
IP/Copyright Situation:  




Implemented as part of the Seaknot EU funded project (HORIZON-EURATOM-2021-NRT-01 under Grant Agreement No. 101060327) - WP2.6 UNIPI (2024-2025)