It consists of an aerosol generator, a mixing vessel, 20 cm diameter circuit composed of two 6 m long straight pipes (one horizontal and one vertical)
Air flow rates, gas and wall temperatures, aerosol mass concentration and size distribution.
References: [1] OECD/CSNI SPECIALIST MEETING ON NUCLEAR AEROSOLS IN REACTOR SAFETY Summary and Conclusions, report NEA/CSNI/R(99)5, held on 15-18 June, 1998 Cologne, Germany.
https://www.oecd-nea.org/upload/docs/application/pdf/2020-01/csni-r99-5.pdf
[2] E. Verloo et al., Study of aerosol deposition in large pipes: Transat programme. Journal of Aerosol Science vol. 27, Suppl. I, pp. S453-S454, 1996. DOI: 10.1016/0021-8502(96)00299-6
[3] V. Saldo et al., 17.P.11 Study of aerosol deposition in large pipes: transat programme, Journal of Aerosol Science, Volume 25, Supplement 1, 267-268, 1994,
https://doi.org/10.1016/0021-8502(94)90364-6.Contributed By: L. Cantrel
IP/Copyright Situation: upon request, partially published