Facility Details: TYFON - CHROMIA

Organization / Localization: ASNR
Country: France
Facility Description: Volume ~120 L, submergence 1 m, thermostated up to 60/70°C
SA-Related Topics / Phenomena: retention of aerosol and gaseous iodine by pool-scrubing
Measured Parameters: Hydrodynamics and retention in pool
Modelling: Models under development/review
Simulation Code: ASTEC
Link to PIRT: ST-20, ST-54 and ST-55
References: [1] F. Djeriouat et al. Experimental study of volatile iodine retention by pool scrubbing: Influence of operating conditions. Chemical Engineering Research and Design 217 (2025) 318–326. https://doi.org/10.1016/j.cherd.2025.03.030
[2] Farhat M. et al. Hydrodynamic aspects of aerosols pool scrubbing. Chemical Engineering Research and Design 191 (2023) 646–657. https://doi.org/10.1016/j.cherd.2023.02.004
[3] Farhat M. et al. Characterization of bubbles dynamics in aperiodic formation. Int. J. Heat Mass Transf. 180 (2021), 121646. https://doi.org/10.1016/j.ijheatmasstransfer.2021.121646
IP/Copyright Situation: upon request and partially published




Implemented as part of the Seaknot EU funded project (HORIZON-EURATOM-2021-NRT-01 under Grant Agreement No. 101060327) - WP2.6 UNIPI (2024-2026)