MCCI with sustained inductive HF-heating of the melt. In tests with metallic melt a neutral coils is installed in front of the metallic layer to act as a magnetic shield. Oxidic corium (max. about 50 kg) is generated in the VULCANO plasma furnace and the
Erosion front, melt temperatures, post test analyses
Melt temperature, 2D concrete erosion vs. Time
References: [1] C. Journeau, et al., “Two EU funded tests in VULCANO assess the effects of concrete nature on its ablation by molten corium”, 4th European Review meeting on Severe Accident Research (ERMSAR-2010), Bologna (Italy), May 11-12, 2010
[2] C. Journeau, et al., "Two-dimensional interaction of oxidic corium with concretes: The VULCANO VB test series", Annals of Nuclear Energy 36, pp. 1597-1613, 2009
https://www.sciencedirect.com/science/article/pii/S0306454909001984
[3] A. Miassoedov, et al., “LACOMECO and PLINIUS Experimental Platforms at KIT and CEA", 4th European Review meeting on Severe Accident Research (ERMSAR-2010), Bologna (Italy), May 11-12, 2010
IP/Copyright Situation: