Organization / Localization: University Wisconsin-Madison/Madison, Wisconsin Facility Description: The WFCI facility consists of a furnace, transfer vessel, upper funnel, test section, slide gate, expansion section, quench tank and trigger. Test Identification: A-01 to A-06, B-01 to B-03, C-01 to C-06, D-01 to D-06, E-01 to E-03, F-02 to F-04 SA-Related Topics / Phenomena:Premixing, Explosion /fragmentation, steam explosion Measured Parameters: Pressure, Temperature, Water level swell, Visualisation Modelling: Fragmentation laws, steam explosion quantification Simulation Code: FCI codes
References: [1] Hyun-Sun Park, Vapor Explosions in One-Dimensional Large Scale Geometry, PhD. Thesis, University of Wisconsin-Madison (1995). IP/Copyright Situation: No
Implemented as part of the Seaknot EU funded project (HORIZON-EURATOM-2021-NRT-01 under Grant Agreement No. 101060327) - WP2.6 UNIPI (2024-2026)