Containment atmosphere mixing/Atmosphere stratification and SAM effect: heater
| Facility Name | Test Identification | Measured Parameters | Modelling | Simulation Code | Experimental Research Program | Country |
|---|
| PANDA | PE4 | Fluid and wall temperatures, absolute and differential pressures, flow rates, heater power, gas concentrations and flow velocities | | LP & CFD | ERCOSAM-SAMARA Project | Switzerland |
|
Implemented as part of the
Seaknot EU funded project (HORIZON-EURATOM-2021-NRT-01 under Grant Agreement No. 101060327) - WP2.6 UNIPI (2024-2026)