dry MCCI

DataBase Ex-Vessel - Molten Corium Concrete Interaction- (MCCI) (1)
Facility NameTest IdentificationMeasured ParametersModellingSimulation CodeExperimental Research ProgramCountry
SURCSURC-1, SURC-2 and SURC4pool temperatures, concrete ablation distance, sidewall heat losses and gas and aerosol compositionTOLBIAC-ICB MELTSPREAD MELCOR WECHSL CORCON COSACO MPS methodOECD/NEA/CSNI-MCCI
▼ Show/Hide Additional Details