Details for SA-Related Topic / Phenomenon: dry MCCI

Molten Corium Concrete Interaction- (MCCI) (1)
Facility NameTest IdentificationMeasured ParametersModellingSimulation CodeExperimental Research Program
SURCSURC-1, SURC-2 and SURC4pool temperatures, concrete ablation distance, sidewall heat losses and gas and aerosol compositionTOLBIAC-ICB MELTSPREAD MELCOR WECHSL CORCON COSACO MPS methodOECD/NEA/CSNI-MCCI
▼ Show/Hide Additional Details




Implemented as part of the Seaknot EU funded project (HORIZON-EURATOM-2021-NRT-01 under Grant Agreement No. 101060327) - WP2.6 UNIPI (2024-2025)