Facility Details: Marviken

Organization / Localization: Swedish Nuclear Power Inspectorate (SKI)
Country: Sweden
Facility Status: closed
Focus area 3: Fission product chemistry, distribution and remobilization behaviour in containment (1)
Facility Description: Large scale test facility for reactor safety experiments
Test Identification: Marviken-V Test 1,2
SA-Related Topics / Phenomena: FP depletion to surfaces under condensing conditions (non-soluble)
Measured Parameters: T, p, FP concentrationn and deposition, range from 25 to 1200 °C
Modelling: Transport and deposition of aerosols and volatile species in a simulated LWR primary circuit
Simulation Code: ECART, AC2, MELCOR, ASTEC, MAAP, GOTHIC
Experimental Research Program: Marviken
Link to PIRT: WP-1.5 ST-15
Show/Hide Additional Details ▼
References: [1] J.O. Liljenzin, J. Collén, W. Schöck, F.J. Rahn Report from the MARVIKEN-V / DEMONA / LACE Workshop Proceedings of the OECD/NEA Workshop on Aerosol Behaviour and Thermal-Hydraulics in the Containment, Fontenay-aux-Roses (France), 26-28 Nov. 1990 CSNI Report No. 17
Contributed By: M. Freitag




Implemented as part of the Seaknot EU funded project (HORIZON-EURATOM-2021-NRT-01 under Grant Agreement No. 101060327) - WP2.6 UNIPI (2024-2026)