| Facility Name | Test Identification | Measured Parameters | Modelling | Simulation Code | Experimental Research Program | Country |
|---|---|---|---|---|---|---|
| THAI | HR-35 (used for code benchmark) | Pressure, temperature, hydrogen and oxygen concentration, velocity profile | PAR operation: Engineering correlations (Framatome, AREVA) and a model with detailed heat and mass transfer process (REKO-DIREKT). | GOTHIC MELCOR COCOSYS GASFLOW CFX | OECD/NEA THAI-2 project | Germany |